Siemens Opcenter X

criticalCVE-2026-56451
View CSAF Summary Opcenter X before V2604 contain an authentication bypass vulnerability that could allow an attacker to gain full unauthorized access to the application. Siemens has released a new version for Opcenter X and recommends to update to the latest version. The following versions of Siemens Opcenter X are affected: Opcenter X vers:intdot/<2604 CVSS Vendor Equipment Vulnerabilities v3 10 Siemens Siemens Opcenter X Improper Verification of Cryptographic Signature Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-56451 Affected applications do not properly validate the algorithm specified in the JSON Web Token (JWT) header. This could allow an unauthenticated remote attacker to forge arbitrary JWT, bypass authentication mechanisms and impersonate any user including administrative accounts, potentially gaining full unauthorized access to the application. View CVE Details Affected Products Siemens Opcenter X Vendor: Siemens Product Version: Opcenter X < V2604 Product Status: known_affected Remediations Vendor fix Update to V2604 or later version https://support.sw.siemens.com/product/206159703/ Relevant CWE: CWE-347 Improper Verification of Cryptographic Signature Metrics CVSS Version Base Score Base Severity Vector String 3.1 10 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H Acknowledgments Siemens ProductCERT reported this vulnerability to CISA. General Recommendations As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional info

CSIRTS triage

What
An authentication bypass vulnerability allows unauthorized access to the application.
Who is affected
Deployments of Opcenter X before version 2604.
Urgency
Immediate remediation is critical due to the potential for unauthorized access.
Action
Update to the latest version of Opcenter X.

AI-assisted analysis generated from the source advisory — verify against the original.

⚡ Watch Opcenter X

Get an email when a new Opcenter X advisory drops — max one per day, one-click unsubscribe.

Details

Source
CISA Cybersecurity Advisories (US · national-cert · site)
Severity
critical
Published
2026-07-21
Exploitation
Not in CISA KEV at last sync

Original advisory: https://www.cisa.gov/news-events/ics-advisories/icsa-26-202-03

Exploitation outlook

EPSS (FIRST.org) estimates each CVE’s probability of exploitation in the next 30 days — here is the CSIRTS.com read on those numbers.

Referenced CVEs

CVECSIRTS overviewExternal
CVE-2026-56451coverage & exploitation statusNVD · CVE.org

Same CVEs, other sources

How other CERTs, PSIRTs and databases cover the vulnerabilities in this advisory.

More from CISA Cybersecurity Advisories