CVE-2024-47736
Actively exploited. CVE-2024-47736 is listed in the CISA Known Exploited Vulnerabilities catalog — exploitation has been observed in the wild, and US federal agencies are required to remediate it under BOD 22-01. Treat patching as urgent.
View CSAF Summary Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version V3.1.6 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or not yet available. The following versions of Siemens SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP are affected: SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0) vers:intdot/>=3.1.6 (CVE-2021-41617, CVE-2023-28531, CVE-2023-51384, CVE-2023-52927, CVE-2024-26783, CVE-2024-27056, CVE-2024-28956, CVE-2024-36903, CVE-2024-36927, CVE-2024-42079, CVE-2024-46786, CVE-2024-47736, CVE-2024-47809, CVE-2024-49968, CVE-2024-49994, CVE-2024-49998, CVE-2024-50014, CVE-2024-50063, CVE-2024-50164, CVE-2024-50298, CVE-2024-53124, CVE-2024-53170, CVE-2024-54458, CVE-2024-56631, CVE-2024-56703, CVE-2024-56719, CVE-2024-57917, CVE-2024-57924, CVE-2024-57973, CVE-2024-57977, CVE-2024-57979, CVE-2024-58011, CVE-2024-58016, CVE-2024-58020, CVE-2024-58056, CVE-2024-58058, CVE-2024-58061, CVE-2024-58086, CVE-2025-21645, CVE-2025-21648, CVE-2025-21655, CVE-2025-21676, CVE-2025-21682, CVE-2025-21702, CVE-2025-21705, CVE-2025-21706, CVE-2025-21707, CVE-2025-21718, CVE-2025-21731, CVE-2025-21745, CVE-2025-21758, CVE-2025-21760, CVE-2025-21764, CVE-2025-21765, CVE-2025-21780, CVE-2025-21795, CVE-2025-21796, CVE-2025-21802, CVE-2025-21814, CVE-2025-21846, CVE-2025-21853, CVE-2025-21861, CVE-2025-21864, CVE-2025-21867, CVE-2025-21875, CVE-2025-21887, CVE-2025-21913, CVE-2025-21919, CVE-2025-21925, CVE-2025-21926, CVE-2025-21938, CVE-2025-21959, CVE-2025-21999, CVE-2025-22005, CVE-2025-22015, CVE-2025-22055, CVE-2025-22056, CVE-2025-22060, CVE-2025-22083, CVE-2025-22090, CVE-2025-22095, CVE-2025-22107, CVE-2025-22111, CVE-2025-22121, CVE-2025-23136, CVE-2025-23143, CVE-2025-37785, CVE-2025-37909, CVE-2025-37917, CVE-2025-37945, CVE-2025-37959, CVE-2025-37964, CVE-2025-37972, CVE-2025-3
CSIRTS triage
- What
- Multiple vulnerabilities have been identified in the firmware of the product.
- Who is affected
- Users of the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP with firmware version 3.1.6 or higher.
- Urgency
- Remediation is urgent as the vulnerabilities are actively exploited.
- Action
- Siemens is preparing fix versions and recommends specific countermeasures.
AI-assisted analysis generated from the source advisory — verify against the original.
⚡ Watch CVE-2024-47736
Get an email if CVE-2024-47736 is added to CISA KEV, gains public exploit code, or a new advisory cites it — max one per day, one-click unsubscribe.
Exploitation outlook
- Exploitation confirmedAlready exploited in the wild (CISA KEV) — the prediction phase is over. Patch now. Riskier than 8% of all EPSS-scored CVEs.
Advisory coverage (2)
- unknownexploitedSiemens SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFPcisa · 2026-07-28
- unknownMultiple vulnerabilities in Siemens products (July 15, 2026)cert-fr-avis · 2026-07-15
External references
Embed the live status
— this badge updates automatically when the KEV or exploit status changes. How to embed it →
[](https://www.csirts.com/cve/CVE-2024-47736)