CSIRTS // UNIFIED SECURITY ADVISORY FEEDSYS ● ONLINE · POWERED BY INTELFUSIONS.COM

CVE-2026-10714

criticalcovered by 3 sourcesfirst seen 2026-07-14
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to impersonate an authorized user on the FTSP server, resulting in unauthorized access to system configurations. The following versions of Rockwell Automation FactoryTalk Services Platform are affected: FactoryTalk Directory (FTSP) 6.60 CVSS Vendor Equipment Vulnerabilities v3 7.8 Rockwell Automation Rockwell Automation FactoryTalk Services Platform Weak Authentication Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-10714 A security issue exists within FactoryTalk Services Platform (FTSP), allowing an attacker to bypass JWT signature validation during Okta Web Authentication. The vulnerability stems from the application not verifying that the JWT algorithm is configured for RSA, enabling an attacker to set the algorithm to "none" and craft forged tokens. This could allow an authenticated low-privilege user to impersonate any authorized user on the FTSP server, resulting in unauthorized access to system configuration and the ability to grant permissions to other systems protected by FTSP. View CVE Details Affected Products Rockwell Automation FactoryTalk Services Platform Vendor: Rockwell Automation Product Version: Rockwell Automation FactoryTalk Directory (FTSP): 6.60 Product Status: known_affected Remediations Mitigation Users using FactoryTalk Services Platform v6.60 should apply either the individual patch (RAID 1158263) or the February 2026 Patch Roll-up, or later update. Mitigation Users using the affected software, who are not able to upgrade to one of the corrected versions, should use Rockwell's security best practices. https://support.rockwellautomation.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight Mitigation For more information, refer to Rockwell Automation's security advisory SD1786 page. https://www.rockwellautoma

CSIRTS triage

What
A vulnerability allows attackers to bypass JWT signature validation.
Who is affected
Deployments of FactoryTalk Services Platform version 6.60.
Urgency
Critical remediation is necessary due to the potential for unauthorized access.
Action
Update to the latest version of FactoryTalk Services Platform.

AI-assisted analysis generated from the source advisory — verify against the original.

⚡ Watch CVE-2026-10714

Get an email if CVE-2026-10714 is added to CISA KEV, gains public exploit code, or a new advisory cites it — max one per day, one-click unsubscribe.

Exploitation outlook

Advisory coverage (3)

External references

NVD record for CVE-2026-10714

CVE.org record

Embed the live status

CVE-2026-10714 live status badge — this badge updates automatically when the KEV or exploit status changes. How to embed it →

[![CVE-2026-10714 status](https://www.csirts.com/badge/CVE-2026-10714)](https://www.csirts.com/cve/CVE-2026-10714)